M4012 Series VPX 3U
VITA 62 VPX SOLUTIONS

Key Features
Product Type:Power Supply (Converter)
Input:16.5-50VDC
Output(s):Six
Output Power:350W
Filters:EMI Filters Included
Efficiency:85%
Operating Temp.:-55°C to 85°C
Designed to Meet:MIL-STD-1275 | DEF Stan 61-5 | MIL-STD-704 | MIL-STD-810 | MIL-STD-461
Compliance:VITA 62
Standard Configurations
Model Power Output 1 Output 2 Output 3 Output 4 Output 5 Output 6
M4012-101 297W 12V @ 15A 3.3V @ 5A 5V @ 12A aux_12V @ 1A aux_-12V @ 1A aux_3.3V @ 5A
M4012-102 251W 12V @ 12A 3.3V @ 5A 5V @ 10A aux_12V @ 1A aux_-12V @ 1A aux_3.3V @ 5A
M4012-103 284W 12V @ 15A 3.3V @ 5A 5V @ 12A aux_12V @ 1A aux_-12V @ 1A aux_3.3V @ 1A
M4012-104 357W 12V @ 20A 3.3V @ 5A 5V @ 12A aux_12V @ 1A aux_-12V @ 1A aux_3.3V @ 5A
M4012-105 297W 12V @ 15A 3.3V @ 5A 5V @ 12A aux_12V @ 1A aux_-12V @ 1A aux_3.3V @ 5A
*Input for this configuration: 16.5 to 50 VDC at Hz
M4012 Additional configurations available

* All of our products can be configured to comply with EU REACH regulations. Contact Us today to learn more.

Custom Designed Solutions

For all your requirements, we’ll custom design a solution to fit your needs

CONTACT US TODAY

To see a complete listing of the unique power attributes and features of each Standard Configuration of this product, please download the associated Catalog Page in the Resources section below.

Custom Designed Solutions

For all your requirements, we’ll custom design a solution to fit your needs

CONTACT US TODAY
Base Specifications
Form Factor:3U
Weight:30.34oz860g
Dimensions:3U, 1"3U, 1"
Holdup:50ms up to 250W
Communication Protocol: I2C
Fixed switching frequency:250kHz
*

Product specifications and features subject to change without notice.
Please contact our factory before placing order.

Output Range(V min to V max @ A max)
#1 V to 12V @ 20A
#2 V to 3.3V @ 5A
#3 V to 5V @ 12A
#4 V to aux 12V @ 1A
#5 V to aux -12V @ 1A
#6 V to aux 3.3V @ 5A
Description

M4012 is a military grade, 3U VPX, 28V DC-DC PSU card that provides six outputs per VITA 62 that is rated at 350W output power and 9-15 Joules of holdup for MIL-HDBK-704-8, LDC201 requirements.  Features include: conduction cooling, reverse battery protection, internal EMI filters. DC input range is 18-50V per MIL-STD-704 and DO-160, but variants support ranges of 12-100V per MIL-STD-1275 and Def Stan 61-5.  Designed to meet MIL-STD-810 and MIL-STD-461.

Tailored Products to Meet Your Requirements
mots

Modified Off The Shelf Solutions

All of our products can be configured to your specific requirements. Customers are invited to work with a design engineer to define the output, input range, protection limits and dimensions of the power solution which best meets their project needs. This can frequently be accomplished without NRE. Use the contact form to submit a request, or contact us to discuss your requirements. For our US team call (603) 267-8865, for our European team call: +41-41-740-4554. Configurations created for specific requirements will be assigned a new variant part number.

Learn More

Milpower Source Inc.

P.O. Box 810
7 Field Lane
Belmont, NH 03220
United States

P: (603) 267-8865

This email address is being protected from spambots. You need JavaScript enabled to view it.

Conflict Mineral Policy

Created by Mark Media Group